Ignition SCADA – development, integration and support

We build and migrate SCADA systems on Ignition by Inductive Automation® – with Ignition Standard, the licence follows the server, not the number of tags or clients.

Common situations we help with

  • Ignition has already been chosen, but there's no integrator covering the whole platform – Gateway configuration, Perspective/Vision interface, database connectivity and script programming
  • The Vision application is difficult to maintain and a move to Perspective is being considered
  • The tag structure lacks UDTs and becomes hard to scale as the facility grows
  • The Ignition Gateway needs to be made more resilient or extended with redundancy
  • Historian and reporting on SQL databases need to be set up or troubleshot
  • Documentation and knowledge are missing after a previous integrator moved on

Services

What we deliver

  • New installation – architecture (gateway network, redundancy, frontend/backend split), servers and tag structure (UDT), screen design in Perspective
  • Ignition Edge at machine and field level – local visualisation and data collection, connected to a central Ignition server
  • Common standards for UDT templates, tag naming and alarms – applied across all plants and by the machine suppliers
  • Integration with PLC (Siemens, Mitsubishi, OPC UA, Modbus TCP/RTU) and SQL databases for historian and reporting
  • Migration from Vision to Perspective, or from legacy SCADA systems (WinCC, AVEVA/Citect, Wonderware, iFIX) to Ignition
  • Production data, traceability and reporting built directly in Ignition (Tag Historian, SQL) without third-party modules – full MES functionality may require additional development or specialised modules
  • Support, troubleshooting and further development of existing Ignition installations
  • Operations and maintenance – version upgrades, patching, licence management, project version control, backup and restore

Buying an Ignition licence?

We help you choose the right edition and modules and help you with the purchase – for new installations, extensions with new modules and renewal of support plans (e.g. TotalCare). Get in touch before you order.

Ask about licensing

From

AVEVA/Citect, WinCC, Wonderware, iFIX, Vision

To

Ignition (Perspective)

  1. 1

    Mapping

    Tags, alarms, history and visualisation in the current system.

  2. 2

    Build and FAT

    Tag structure (UDTs), screens, alarms and history in Ignition – verified in FAT.

  3. 3

    SAT and cut-over

    SAT on site, operational continuity during the transition and a documented rollback plan.

  4. 4

    Handover

    Documentation, knowledge transfer and post-commissioning support.

Process

How we work

  1. 1

    Technical call
    (30 min, free)

    We walk through your facility, systems and goals.

    Book directly
  2. 2

    Assessment and recommendation

    Clear scope, risks and a proposal for delivery – at a fixed price or on a time-and-materials basis.

  3. 3

    Delivery

    Programming, testing and phased commissioning designed to minimise production downtime.

  4. 4

    Handover and support

    Documentation, knowledge transfer to your team and support after commissioning.

Why Ignition?

In Sweden, Ignition is not yet as common as established systems such as WinCC, AVEVA (formerly Citect and Wonderware) or iFIX. Here is why we choose it for new projects anyway:

  • Ignition Standard: per-server licensing, not per tag or client – often a lower total cost when scaling. Licence scope depends on the modules and architecture chosen
  • Built-in drivers for many common PLC families and databases, plus OPC UA for the rest – without third-party middleware
  • The same platform scales from a single machine to a facility with multiple gateways

Technologies

Perspective vs Vision – which module fits your facility?

Perspective

Web-based, responsive interface that runs in any browser – desktop, tablet or mobile, with no installation on the client side. On operator stations, the same project can run as a standalone app (Perspective Workstation), without the browser address bar and across multiple monitors. We recommend Perspective as the default choice for new projects: one project reaches the control room, a tablet in the field and a phone, login can be tied to the company identity provider (SSO), and the interface is built on web technology (HTML5, CSS, React) – screens are built from reusable components, and custom stylesheets and components can be integrated.

Vision

The original, Java-based client interface in Ignition. Stable and well-proven. We use Vision primarily to extend and maintain existing installations where switching to Perspective isn't justified on cost or time grounds.

Perspective Vision
Interface Browser (HTML5) Java client
Client-side installation No (browser) Yes (Ignition Launcher)
Mobile-friendly Yes No
Suited for New projects, mobile access Existing Vision installations

Operator interfaces

Perspective

Browser, tablet, phone

Vision

Java client (Ignition Launcher)

Ignition Gateway

  • Tags and UDTs
  • Alarms
  • Tag Historian
  • Reports
  • Scripting
  • Users and roles

Connected systems

  • SQL database History and reports – MS SQL Server, MySQL/MariaDB, PostgreSQL
  • MES Traceability and production data

Communication

  • OPC UA
  • Siemens S7
  • Mitsubishi MELSEC
  • Modbus TCP/RTU

Field level

PLC

Siemens S7, Mitsubishi MELSEC, CODESYS

Simplified schematic – number of gateways, redundancy and network zones are tailored to the plant.

OT security in Ignition environments

An unsecured Ignition Gateway is a production and operational risk, not just an IT issue. We harden Ignition installations in line with IEC 62443 principles: network segmentation, access control and authenticated, encrypted remote access to the Gateway and clients – built in from the start.

  • Network segmentation, access control and event logging in line with IEC 62443 principles
  • Authenticated, encrypted remote access to the Ignition Gateway, Perspective and Vision

Experience

Proven in production

Ignition SCADA system with thousands of tags, several SQL databases and dozens of dashboards.

Automotive manufacturing

Connected over 300 machine cells and robot stations to SCADA/MES via OPC UA, S7 and ISO-on-TCP, across engine machining, gearbox manufacturing and battery production. Ignition SCADA system with thousands of tags, several SQL databases and dozens of dashboards. A real-time alarm system that flags process deviations the moment they occur.

Certifications

Certified where it counts

2026

Ignition 8.3 Credentialed

Inductive Automation

2023

OT Cybersecurity Training - IEC 62443

Training Center for Automation Systems INTEX, Gliwice

FAQ

Common technical questions

Perspective or Vision for a new facility?

Perspective – it runs in any browser, including tablets and phones, with no client-side installation. We mainly use Vision to extend existing installations where a switch is not justified.

How is Ignition licensed?

Ignition Standard is licensed per server, not per tag or client – often a lower total cost as the plant grows. The licence scope depends on the chosen modules and system architecture – we help you choose and with the purchase. For individual machines and field devices there is Ignition Edge: a lower-cost licence with unlimited tags and devices, but at most two concurrent clients, 35 days of local history and no database connectivity – often connected to a central Ignition server.

Can Ignition communicate with our existing PLCs?

Yes. Ignition has built-in drivers for many common PLC families and databases, plus OPC UA for the rest – without third-party middleware. We integrate with Siemens, Mitsubishi, OPC UA and Modbus TCP/RTU.

Can you migrate Vision to Perspective, or WinCC/Citect to Ignition?

Yes, both. We map tags, alarms, history and visualisation, and plan the transition for operational continuity with a documented rollback plan.

Can you take over an Ignition installation from another integrator?

Yes. Support, troubleshooting and further development of existing Ignition installations are part of what we deliver – including when documentation is missing.

Contact

Let's discuss your project

Whether you have a detailed specification or just a first idea – we're happy to have a technical conversation and help you find the right path forward.

We respond to every enquiry within 24 hours, on business days.

We process your details to respond to your enquiry. More information is in our privacy policy.

Based in Stockholm. Assignments across Sweden, on-site and remote – abroad by arrangement. Professional liability insurance in place for all assignments.

Book a call (30 min) Call